As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FTW - FOUND AFT PIT ENLARGED HOLE ON SUPPORT CHANNEL STATION 1212, L27R. UPON FURTHER INVESTIGATION SUPPORT CHANNEL FOUND TO HAVE CORROSION. REMOVED SUPPORT CHANNEL. FABRICATED REPAIR SUPPORT CHANNEL. INSTALLED REPAIR SUPPORT CHANNEL. (M)