As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT STA 1309 FLOORBEAM CORRODED AT LOWER SIDE LBL 30-RBL 30. CUT FLOORBEAM AT STA 1309 LBL 33. FABED 2 EA L ANGLES. FABRICATED NEW FLOORBEAM AND SPLICE DOUBLER. RT OB FITTING OUT OF LIMITS. FABRICATED FLOORBEAM SUPPORT ANGLE. INSTALLED FLOORBEAM. 2 EA (L) ANGLES SPLICE DOUBLER AND SUPPORT FITTING.