What was found
FOUND CABIN STATION 541-617 STRINGER 18L AND STATION 636-712 STRINGER 18L FLOOR WEB CORRODED IN NUMEROUS AREAS. MATERIAL LOSS IS OUT OF LIMITS STATION 636-655 AT STATION 642-647. CUT OUT AREA. FORMED FILLER AND REPAIR DOUBLER. INSTALLED FILLER AND DOUBLER STATION 633-655. (M)