As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
THE RIGHT RED GEAR UNSAFE LIGHT DID NOT EXTINGUISH AFTER GEAR RETRACTION. THE AMBER GEAR DOOR OPEN LIGHT CAME ON WHEN HYD PUMPS WERE SELECTED TO LOW PSI. CHECKED HYD PUMPING, GEAR AND DOOR MECH ON RIGHT GEAR. NO DEFECTS NOTED REMOVED AND REPLACED RIGHT GEAR UPLOCK SENSOR. REMOVED AND REPLACED PROX SWITCH P/N 833703, ELECT UNIT. (M)