AFT PIT OVERHEAD FLOORBEAM INTERCOSTAL CRACKED AT (4 EA) PLACES ALONG FASTENER HOLES, FS 1287-1309. REMOVED FLOORBEAM INTERCOSTAL AT FS 1287-1309, FABRICATED NEW INTERCOSTAL SRM 51-10-2 FROM 7075-T6-.063. HEAT TREATED NEW INTERCOSTAL, LOCATED AND DRILLED HOLES FOR NEW INTERCOSTAL, TREATED, PRIMED, TOP COATED, INSTALLED NUT PLATES AND INSTALLED NEW INTERCOSTAL IAW SRM 51-30-5, 51-30-2.