What was found
LT WING L/E CHAFED ON EXTERNAL SURFACE AT STA XRS 240, XRS 164, XRS 137. BLENDED OUT CHAFED AREAS IAW SRM 57-01, FIG 1, MATERIAL LOSS AT XRS 137 AND 240 OUT OF LIMITS, FABRICATED 2EA REPAIR DOUBLERS FROM 7075-T6-.063, LOCATED DRILLED REPAIR DOUBLERS, TREATED, PRIMED AND INSTALLED REPAIR DOUBLERS IAW SRM 57-06B, FIG 14 AND 51-30-5.