What was found
SKIN DENT AT STA 1174, BETWEEN LONGERON 17L AND 18L. REMOVED SAF-T-GLO, GALLEY 4 AND SIDE WALL PANEL TO FOM AT LT FS 1184. FOUND DENT TO BE (D=1.5 INCH, X=0.050, D/X=30) COND 2. REFORMED DENT AREA TO ORIGINAL CONTOUR. INSTALLED DOUBLER IAW SRM 53-04, FIG 38. INSTALLED SIDE WALL PANEL, G4 GALLEY AND SAF-T-GLO IAW MM. (K)