As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT SUBFLOOR AT LEFT CUSP CORRODED FROM STATION 1022-1041. REMOVED PANELS FOR ACCESS. REMOVED CORROSION FOUND IS OUT OF LIMITS. CUT OUT DAMAGED AREA, FABRICATED WEB AND DOUBLER. TREATED AND PRIMED, INSTALLED REPAIR TWO FITTINGS. RE-INSTALLED REMOVED ACCESS PANELS. (M)