What was found
R1 DOOR NOT SHOWING CLOSED INFLIGHT ON ECAM. RECYCLED EMERGENCY LIGHT TEST SWITCH ON FAP AND DOOR LIGHTS WORKED NORMALLY. PERFORMED ADJUSTMENT OF R1 DOOR PROX SWITCH PER AMM. SYSTEM OPS CHECK GOOD, LP NR 179708-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 DOOR NOT SHOWING CLOSED INFLIGHT ON ECAM. RECYCLED EMERGENCY LIGHT TEST SWITCH ON FAP AND DOOR LIGHTS WORKED NORMALLY. PERFORMED ADJUSTMENT OF R1 DOOR PROX SWITCH PER AMM. SYSTEM OPS CHECK GOOD, LP NR 179708-3. (M)