What was found
NR 2 ENGINE-DENT/SCRATCH FOUND ON ENGINE UP DURING WALK AROUND PERFORMED DIMENSION CK, DENT IS 2.7500" X 1 " AND J04 DEEP. OUT OF LIMITS REQUIRES NOSE COWL CHANGE. REMOVED DAMAGED COWL, INSTALLED ROBBED PART FROM A/C 522 IAW AMM 71-11-11, NEEDS OPS TEST, ACCOMPLISHED OPS TEST OF THE P2/T2 PROBE HEATER, AND ANTI ICE SYS FAULT WARNING OPS CHECK ON IAW AMM 73-22-11/30-21-00.