What was found
CLASS II MESSAGE SMOKE AND CARGO SMOKE DETECTOR FAULT IN FLT. CREW DISCHARGED FIRE AGENT FOR CARGO. R & R CARGO FIRE BOTTLE ASSY IAW AMM 26-23-42. CHECK OF FIRING CIRCUIT CONTINUITY C/W IAW AMM 26-23-00. CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLASS II MESSAGE SMOKE AND CARGO SMOKE DETECTOR FAULT IN FLT. CREW DISCHARGED FIRE AGENT FOR CARGO. R & R CARGO FIRE BOTTLE ASSY IAW AMM 26-23-42. CHECK OF FIRING CIRCUIT CONTINUITY C/W IAW AMM 26-23-00. CHECKED GOOD.