What was found
FLAPS LOCKED FROM POSITION 1 TO POSITION 2 DURING FINAL APPROACH. ACCOMPLISHED TROUBLESHOOTING IAW TSM 27-51-00-810-818-A. FOUND THE RT FLAP INTERCONNECTING STRUT OUT OF ADJUSTMENT, ADJUSTED THE STRUT IAW AMM 27-51-44. PERFORMED AN OPS CHECK IAW AMM 27-51-44, & 27-54-00. NO DEFECTS NOTED. OPS CHECKED GOOD.