What was found
L2 DOOR VERY HARD TO OPEN . FOUND THE DOOR DAMPER CYLINDER LINKAGE TO THE DOOR LOWER BRACKET, BONDED BUSHING MIGRATED OUT AND WEDGED BETWEEN THE DOOR AND DOOR FRAME. REPLACED THE BONDED BUSHING IAW AMM 52-10-00. L2 DOOR OPS CHECKED GOOD IAW AMM 52-10-00.