Service difficulty report · Acm · Airbus A319132

Difficulty date
September 28, 2017
Submitted
October 3, 2017
Operation
Air carrier
Aircraft
N515NK
Make and model
Airbus A319132
Aircraft time
35,402 hours, 19,565 cycles
Part
Acm
Condition
Odor
Location
Nr 2
Stage of operation
DE
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHEN DESCENDING THROUGH 3,000 FT, FA CALLED AND REPORTED A STRONG DIRTY SOCK ODOR IN CABIN. TURNED OFF THE NR 2 PACK AND FA REPORTED THAT THE ODOR DISIPATED AT OR BELOW FL 370. R & R THE NR 2 PACK PLENUM CHAMBER IAW AMM 21-52-22. R & R THE PIPE SEALS FROM ACM TO PRI. HEAT EXCHANGER AND PIPE SEALS FROM ACM TO MAIN HEAT EXCHANGER IAW AMM 21-52-23. OPS CHECKED GOOD.