What was found
DURING DESCENT, F/A REPORTED A BURNING OIL ODOR IN THE AFT GALLEY AREA. APPLIED COM FUME PROCEDURE E AND FUMES DISSIPATED IAW TSM 05-50-00. ODOR WAS LOCALIZED TO THE AFT GALLEY AREA. R & R THE AFT LAVATORY FILTER AS A PRECAUTION IAW AMM 21-23-00. RAN THE NR1 ENGINE, AND NR 1 PACK, NO ODOR. RAN THE NR 2 ENGINE, AND NR 2 PACK, NO ODOR IAW AMM 71-00-00. ACFT OK FOR SERVICE.