What was found
F/CTL SLATS FAULT DURING DESCENT. SLAT STAYED LOCKED AT 0 FLAPS EXTENDED NORMALLY TO POSITION 3 PER COM PROCEDURE. FOUND TORQUE LIMITER POPPED ON LT SLAT. ACTUATOR (6037CM) R/R IAW AMM 27-84-49 OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
F/CTL SLATS FAULT DURING DESCENT. SLAT STAYED LOCKED AT 0 FLAPS EXTENDED NORMALLY TO POSITION 3 PER COM PROCEDURE. FOUND TORQUE LIMITER POPPED ON LT SLAT. ACTUATOR (6037CM) R/R IAW AMM 27-84-49 OPS CHECK GOOD.