What was found
FUME EVENT THROUGH 8000'-REF LOG PGS 2480796-1; -2 FOR CORRECTIVE ACTIONS. ACCOMPLISHED ECS DECONTAMINATION IAW AMM 21-00-00 PB201 R&R RECIRCULATING FILTER IAW AMM 22-21-14 PB401. NO FURTHER FUMES NOTED AT THIS TIME. NR 1 & NR 2 ENG DEOILERS NO LEAKS NOTED.