As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYD ENG 2 PUMP LO PR IN FLIGHT. PERFORMED INSPECTION OF YELLOW SYS HYD SYS FOUND YELLOW ACCUMULATOR AND YELLOW RESERVOIR DRAIN VLV LEAKING REMOVED AND REPLACED DRAIN VLV IAW AMM 29-12-35 REMOVED AND REPLACED YELLOW ACCUMULATOR. IAW AMM AMM 29-13-42 OPS CHECK/ LEAK CHECK GOOD. REMOVED AND REPLACED PRESSURE GAUGE IAW AMM 29-13-21. OPS CHECK GOOD.