What was found
CORROSION FOUND R/H WSC PANELS RIB 9-10 R/H SPAR OVERHANG DIMENSIONS L=120MM W=40MM D=0.94 OST = 5MM RAF 01 2569249-2 OPENED-REVIEWED LTPR NRI 5000903089-0010 , AND HAS BEEN ACCOMPLISHED.REPAIR PERFORMED AS PER EO 5721-1912 REV.00,EMBODIED REPAIR IS CAT B' AS PER AIRBUS RDAS REF 80701996/003/2019 ISSUE A.INSPECTIONS TOP SKIN PANELS BETWEEN RIB 9-10 AT THE REAR ATTACHMENT COVER BY PLATE THRESHOLD 21700FC/434FH INSTERVAL 1000FC METHOD SDI + DETAIL