What was found
AFT FAS REPORT DIRT LAUNDRY ODOR MID TO AFT A/C ON DESCENT TO LANDING, PER TSM 71-00-00-810-847-A. FOUND ENGINE 2 SPINNER CONE TO BE LEAKING OIL. R & R SPINNER CONE COVER SEAL, PER AMM 72-15-00. LEAK CHECK GOOD. ENGINE WASH ACCOMPLISHED, PER MX CONTROL AND TI 7200-1926. ACCOMPLISHED PACK BURNOUT ON PACK 2, PER AMM 21-00-00. SAMPLED AIR WITH AREOTRACER, NO CONTAMINATION DETECTED. A/C OK FOR SERVICE.