What was found
FUME EVENT DURING DESCENT ISOLATE TO PACK 1 FLIGHT DECK AREA GMM 30.40.01 (PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED). PERFORMED DECONTAMINATION OF THE ECS, IAW AMM 21-00-00. APPLIED TSM 05-50-00-810-831-A. OPERATED PACK 1 AND CHECKED FOR CONTAMINATION WITH AEROTRACER TOOL NK13286T. NO CONTAMINATION DETECTED, TYPE 1 THROUGH 10. THIS CLEARS DMI 272752301. MOC NOTIFIED. PLACARD REMOVED.