As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYD Y RSVR OVHT DURING DEPARTURE CLIMB. PERFOMED ECAM TURN OFF HYD PUMP #2 15-20 THE OVER WENT AWAY-PERFORMED INITIAL FLIGHT CONTROL OPERATION FOR 15 MIN, NO FAULTS WHERE NOTE IAW 29-13-00. R&R'D OF THE SYSTEM PRESSURED SWITCH IAW AMM 29-32-12, ALSO PERFORMED OP CHECK AND FOUND OK FOR CONTINUOUS SVC.