As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYD G RSV LO LVL IN FLIGHT-PERFORMED PRESSRIZATION OF GREEN HYD SYSTEM IAW AMM 29-23-00. FOUND LEAK FROM GREEN POWER ACCUMULATOR 1070GM & BOTTOM UNION. REMOVED ACCUMULATOR & FOUND DAMAGE TO UNION & ACCUMULATOR THREADS & ORING MISPLACED