What was found
DESCENDING THROUGH 10,000 DIRTY SOCK SMELL IN CABIN & COCKPIT. TROUBLESHOOTING LED TO PACK 1 + 2 FAULT. SMELL DEISSIPATED.-PERFORMED TSM 05-50-00-810-831-A. INSP. APU, FOUND TO BE SERVICED TO PROPER LEVEL AND NO LEAKS NOTED. INSP. BOTH ENG 1 AND 2 FOUND TO BE SERVICED TO PROPER LEVEL AND NO LEAKS NOTED AT THIS TIME. INSP. BOTH PACK 1 AND 2 BAYS, FOUND TO BE IN SERVICEABLE CONDITION. WHEN PACKS ARE ON WITH BLEED SOURCE BEING ENG 2, CONT. NEXT ITEM