What was found
DIRTY SOCK SMELL THROUGHTOUT AIRPLANE IN DESCENT BELOW 15,000 FT TO LANDING-REF T/C TI 2100-2004-CEO CRONIC QUALITY T/C AND CLEANING. FOUND RESIDUAL OIL IN APU INLET. CLEANED INLET IAW AMM 12-21-00. RAN APU AND PERFORMED LEAK CHECK IAW AMM 49-00-00, LEAK CHECK GOOD. PERFORMED ECS CLEANING PACK 1 & 2 IAW AMM 21-00-00. R&R RECIRCULATING FILTERS AS PRECAUTIONARY MEASURE IAW AMM 21-21-41. RAN ENG 1 & 2 IAW AMM 71-00-00. CONTINUED ON LP 3292171 ITEM 2.