As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON CLIMB THROUGH 10000 WET SOCKS FUME EVENT CONFIRMED WITH FLT ATTENDANTS IN FWD CABIN ISOLATED PACK 1 OFF PER PROCEDURE. FUMES DISPATED. SPIRIT AIR QUALITY REPORTING FORM FILLED OUT.-PERFORMED FAULT ISOLATION PROCEDURES PER TSM 05-50-00-810-831-A. FOUND PACK 1.AS THE FUME SOURCE. REFER TO LP 3458178 ITEM 2