Service difficulty report · Control Valve · Airbus A320271N
FAA SDR system
- Difficulty date
- December 8, 2024
- Submitted
- December 10, 2024
- Operation
- Air carrier
- Make and model
- Airbus A320271N
- Aircraft serial
- 10107
- Aircraft time
- 15,066 hours, 6,333 cycles
- Part
- Control Valve
- Condition
- Leaking
- Location
- Zone 100
- Stage of operation
- NR
- How discovered
- O
- Nature of condition
- B
- Precautionary procedure
- O
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
POSSIBLE FUME EVENT.-PERFORMED FAULT ISOLATION IAW TSM 05-50-00 INSPECTED #1 & #2 ENGS FOR EXTERNALL LEAKS NON NOTED, INSPECTED APU OIL QTY AND FOR EXTERNAL LEAKS SATISFACTORY. FOUND #1 PACK OZONE FILTER TO FLOW CTL VLV INTERFACE LEAKING & INSULATION BLOWN OUT REF LOG PG 3601013-1 & -2 FOR CORRECTIVE ACTIONS