As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C/B TRIPPED ON OVHD PANEL C13 HYD GREEN ENG 1 FIRE-PERFORMED INSPECTIONN OF ENG #1 PUMP FIRE VALVE IAW AMM 29-11-52 CHECKED VOLTS ON CONNECTOR GOING TO PUMP (1046GK) PIN AA AND GOT CORRECT 28 VDC. PERFORMED OPS CHECK OF SHUT OFF VALVES & INDICATING IAW AMM 29-10-00 TEST FAILED ON STEP 4.4 VALVE STAYED OPEN HYD DID NOT TURN AMBER