As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION WAS FOUND ON INNER BORE HINGE FITTING N6 AT LH ELEVATOR RAF-01 3550341-01 GENERATED-REPAIRED BOTH BORES AND REPLACED BUSHING (2EA) ON HINGE FITTING#6 LH ELEVATOR P/N: D5528000200200 S/N: 1C8114 IAW SRM 55-26-41-300-006, THIS REPAIR IS CATEGORY B MUST BE INSPECTED THRESHOLD FROM COMPONENT FIRST FLIGHT 6 YEARS AND SUBSEQUENT INSPECTION A INTERVALS OF 6 YEARS