What was found
CORROSION WAS FOUND ON INNER BORE HINGE FITTING N4 AT LH ELEVATOR RAF-01 3550341-02 GENERATED-REPAIRED BOTH BORES AND REPLACED BUSHING (2EA) ON HINGE FITTING #4 LH ELEVATOR P/N: D5528000200200 S/N: 1C8114 IAW SRM 55-26-41-300-005, THIS REPAIR IS CATEGORY B. THIS REPAIR MUST BE INSPECTED THRESHOLD OF FROM COMPONENT FIRTS FLIGHT 6 YEARS AND SUBSEQUENTS INSPECTION AT INTERVALS OF 6 YEARS.