What was found
EPSU SYSTEM TEST PRODUCES MULTIPLE FAULTS. FOUND CONNECTOR LOOSE AT 10WL IAW AMM 33-51-02 P0151, TSM 33-51-00-810-A AND AMM 33-51-38-400-001-A PARA 4, STEP 78. OPS CHECKED GOOD IAW AMM 33-51-00-710-001-A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EPSU SYSTEM TEST PRODUCES MULTIPLE FAULTS. FOUND CONNECTOR LOOSE AT 10WL IAW AMM 33-51-02 P0151, TSM 33-51-00-810-A AND AMM 33-51-38-400-001-A PARA 4, STEP 78. OPS CHECKED GOOD IAW AMM 33-51-00-710-001-A.