What was found
CRACK INDICATION ON RT FRAME 68 STOP FITTING 6 AT AFT GALLEY AREA FROM LOWER INBD HOLE OF DOOR RAF-01 60233854-02 GENERATED. -PERFORMED REPAIR ON RH FRAM 68 LOWER INBOARD HOLE OF DOOR FITTING 6 AT AFT GALLEY AREA IAW SRM 53-41-12-300-008 SRM 53-41-12-300-010, DWG D534800820, & AMM 52-13-31-400-002-A REPAIR IS CATEGORY B INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT 24500FC (FH NO RELEVANT) SUBSEQUENT INSPECTION AT INTERVAL OF 10700FC IAW SRM 53-41-12-205-009