What was found
STALL WARNING STICK SHAKER ACTIVATED 240 KTS CLEAN, PULLED P35 PER FCOM. SWAPPED NR 1 AND NR 2 STALL WARN COMP. FOUND BOTH INDICATOR PINS POPPED ON NR 1 STALL WARNING COMPUTER. RESET AND SELF TESTED SYSTEM. SYSTEM OPS CHECKS GOOD. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STALL WARNING STICK SHAKER ACTIVATED 240 KTS CLEAN, PULLED P35 PER FCOM. SWAPPED NR 1 AND NR 2 STALL WARN COMP. FOUND BOTH INDICATOR PINS POPPED ON NR 1 STALL WARNING COMPUTER. RESET AND SELF TESTED SYSTEM. SYSTEM OPS CHECKS GOOD. (M)