Service difficulty report · Fuel Control · Doug DC941

Difficulty date
July 9, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N130NK
Make and model
Doug DC941
Aircraft serial
47604
Engine
Pwa JT8D9A
Part
Fuel Control
Condition
Out Of Trim
Location
Nr 1 Engine
Stage of operation
TO
Nature of condition
J
Precautionary procedure
C, D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LOG PAGE 07467. ABORTED TAKEOFF. NR 1 ENGINE WOULD NOT PRODUCE TAKEOFF POWER MAX EPR 1.93 MAX N1 94.1 PERCENT, N2 100.1 PERCENT. CHECKED PT2 LINES FOR LEAKS, BLEW OUT (CLEANED). PERFORMED ENGINE TRIM RUN PER MM 71-00. ALL INDCATIONS CHECK NORMAL. LOCAL TEMPERATURE DROPPED 12 DEGREES. (X)

More about the Doug DC-9-41