What was found
MHV - FORWARD LAVATORY FLOOR PANEL FS 200 TO 237 HAS SEVERAL FASTENER HOLES WITH CRACKS AND SURFACE CORROSION AROUND SCREW HOLES. REMOVED AND REPLACED SKIN AND DOUBLERS IAW 51-10-0, 51-10-2, 51-10-3, 51-10-4 AND 51-30-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MHV - FORWARD LAVATORY FLOOR PANEL FS 200 TO 237 HAS SEVERAL FASTENER HOLES WITH CRACKS AND SURFACE CORROSION AROUND SCREW HOLES. REMOVED AND REPLACED SKIN AND DOUBLERS IAW 51-10-0, 51-10-2, 51-10-3, 51-10-4 AND 51-30-3. (M)