What was found
MHV - FLOOR PANEL NR 2A HAS SEVERAL SMALL CRACKS AT THE END ROW OF RIVET HOLES. STOP DRILLED HOLE AND ADDED DOUBLER IAW 51-10-3, SRM 51-10-4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MHV - FLOOR PANEL NR 2A HAS SEVERAL SMALL CRACKS AT THE END ROW OF RIVET HOLES. STOP DRILLED HOLE AND ADDED DOUBLER IAW 51-10-3, SRM 51-10-4. (M)