What was found
MHV - FLOOR PANEL HAS BREAK OUT FROM ONE FASTENER HOLE ALONG EDGE AND TWO EACH EDGE STRIPS MISSING. FABRICATED PATCH IAW SRM 55-01. TREATED AND PRIMED PATCH IAW SRM 51-10-03. INSTALLED PATCH WITH RIVETS IAW SRM 51-30-2. FABRICATED EDGE STRIPS IAW MM 53-20-1. INSTALLED AND BONDED WITH SCOTCH GRIP IAW MM 20-20-0. (M)