As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MHV - AFT FLOOR PANEL S/N 2686 AND END DELAMINATED ALONG EDGE AND CRACKED IN LOWER ANGLE ALONG DELAMINATION. REPAIRED DELAMINATION PER SRM 53-05. STOP DRILLED CRACK PER SRM 53-01 AND REPAIRED PER SRM 53-05. FABRICATED REPAIR DOUBLERS PER SRM 53-05. ALODINED AND PRIMED PER SRM 51-10-3. INSTALLED REPAIR DOUBLERS PER SRM 53-05. (M)