What was found
MHV - FLOOR WEB HAS CORROSION AT STATION 902 RBL 59 ZF1 AND STATION 908 RBL 59 HAS EVIDENCE OF CORROSION BETWEEN WEBS. FABRICATED AND REPLACED CORRODED WEB IAW 51-10-3/51-30-0. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MHV - FLOOR WEB HAS CORROSION AT STATION 902 RBL 59 ZF1 AND STATION 908 RBL 59 HAS EVIDENCE OF CORROSION BETWEEN WEBS. FABRICATED AND REPLACED CORRODED WEB IAW 51-10-3/51-30-0. (M)