Service difficulty report · Oxygen Line · Doug DC932

Difficulty date
February 23, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N947ML
Make and model
Doug DC932
Aircraft serial
47514
Part
Oxygen Line
Condition
Leaking
Location
Cabin
Stage of operation
IN
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

YIP - DURING FUNCTIONAL CHECK OF OXYGEN MASK DEPLOYMENT TEST, FOUND DEFECTIVE LEAKING LINE AT SUPPLY MANIFOLD (L13 OVERHEAD PANEL LOCATION). REQUIRES LEAK CHECK. SERVICEABLE LINE INSTALLED IAW DC-9 MM 35-20-2. NO LEAKS NOTED. (X)