What was found
MHV - COCKPIT FLOOR AT STATION 117 RBL 3 INCH FROM CENTER LINE EXISTS DENTS AND A CRACK .823 INCH LONG THROUGH SUB STRUCTURE BARRIER FLOOR AND PLASTIC CABLE SHROUD. REMOVED DAMAGED AREA, FABRICATED AND INSTALL DOUBLERS PER SRM 53-01 FIG 2, 51-10-03, 51-30-02, 51-20-0. (M)