What was found
MHV - LOWER CARGO DOOR JAMB PAN REQ 2 EACH -19 AND -21 SPLICE ANGLE REPAIR. FABRICATED ANGLES -19 AND -21 PER DC9 IAW SRM 53-05 PAGE 107 AND 114 FIG 44 SHT 5 SECTION G-G. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MHV - LOWER CARGO DOOR JAMB PAN REQ 2 EACH -19 AND -21 SPLICE ANGLE REPAIR. FABRICATED ANGLES -19 AND -21 PER DC9 IAW SRM 53-05 PAGE 107 AND 114 FIG 44 SHT 5 SECTION G-G. (M)