What was found
AT SCHEDULED INSPECTION DISCOVERED LT ELEVATOR CENTER HINGE BRACKET HAS EXFOLIATION. REPLACED LT ELEVATOR CENTER HINGE BRACKET.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT SCHEDULED INSPECTION DISCOVERED LT ELEVATOR CENTER HINGE BRACKET HAS EXFOLIATION. REPLACED LT ELEVATOR CENTER HINGE BRACKET.