What was found
DURING SCHEDULED ROUTINE MX DISCOVERED RUDDER UPPER HINGE BRACKET HAS EXFOLIATION. REPLACED RUDDER UPPER HINGE BRACKET
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED ROUTINE MX DISCOVERED RUDDER UPPER HINGE BRACKET HAS EXFOLIATION. REPLACED RUDDER UPPER HINGE BRACKET