What was found
DURING SCHEDULED ROUTINE STRUCTURAL INSP, DISCOVERED LT EMERGENCY DOOR LINKAGE OPEN AND CLOSE STIFF AND NOT WORKING CORRECTLY. CLEANED AND LUBRICATED LT EMERGENCY DOOR LOCKING MECHANISM, OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED ROUTINE STRUCTURAL INSP, DISCOVERED LT EMERGENCY DOOR LINKAGE OPEN AND CLOSE STIFF AND NOT WORKING CORRECTLY. CLEANED AND LUBRICATED LT EMERGENCY DOOR LOCKING MECHANISM, OPS CHECK GOOD.