What was found
DURING CRUISE FLIGHT, THE STALL HORN SOUNDED WITH ALL FLIGHT INSTRUMENTS NORMAL AND NOTICED AN ELECTRICAL ODOR, PERFORMED AN UNSCHEDULED LANDING. THE STALL VANE TRANSDUCER FAILED AND CAUSED THE ELECTRICAL ODOR, UNIT WAS REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CRUISE FLIGHT, THE STALL HORN SOUNDED WITH ALL FLIGHT INSTRUMENTS NORMAL AND NOTICED AN ELECTRICAL ODOR, PERFORMED AN UNSCHEDULED LANDING. THE STALL VANE TRANSDUCER FAILED AND CAUSED THE ELECTRICAL ODOR, UNIT WAS REPLACED.