What was found
DURING CHECK, FOUND CORROSION ON BOTTOM OF FLOOR BEAM VERTICAL SUPPORT 19 INCHES RIGHT OF CENTER LINE AT FRAME ATTACH POINT. REPLACED VERTICAL SUPPORT AS PER SRM 51-01-00-05. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK, FOUND CORROSION ON BOTTOM OF FLOOR BEAM VERTICAL SUPPORT 19 INCHES RIGHT OF CENTER LINE AT FRAME ATTACH POINT. REPLACED VERTICAL SUPPORT AS PER SRM 51-01-00-05. (M)