What was found
CABIN FLOOR BEAM STA 1151 RBL= 20 INCHES LEVEL 2 CORROSION ON UPPER SURFACE. REPAIRED CABIN FLOOR BEAM STA 1151 RBL= 20 INCHES PER SRM 53-05, FIG 20 BY FABRICATING FILLER, DOUBLER AND RUB STRIP PER SRM 53-05, FIG 20; CUTTNG OUT DAMAGED AREA, TREATING AREA AND PARTS SRM 51-10-3. INSTALLED COMPLETE PER SRM 53-05, FIG 20 AND SRM 51-30-2. TOTAL TIME: 29,567 HOURS. TOTAL CYCLES, 73,626. (X)