What was found
AFT ACCESSORY COMPARTMENT, INTERNAL, LEVEL 2 CORROSION ON SKIN LAP JUST ABOVE LONGERON IAR FROM STA 1190 TO STA 1247. REMOVED CORROSION SRM 53-01 FIG 1 AND SRM 51-10-3, AND INSTALLED FAB DOUBLER OVER BLADE AREA PER SRM 53-04 FIG 12B, SRM 51-30-2, AND PER DAC ACTION NR 327019 DATED MARCH 26, 1997. TOTAL TIME: 29,567 HOURS. TOTAL CYCLES, 73,626. (X)