What was found
AFTER STARTING APU. APU FAULT ECAM MESSAGE, SHUT DOWN THE APU IAW ECAM. ECAM MESSAGE, LUBE PUMP FILTER & GEN SCAV FILTER 5100KT9. INSPECTED BOTH OIL LUBE FILTER AND GEN SCAV FILTERS IAW TSM 49-62-00-810-916-A. NO FINDINGS OF METAL. DPI ON LUBE FILTER TRIPPED. RESET CHECK. REPLACED FILTER ELEMENTS. OK FOR SERVICE.